Skip to main content

Fluke 1587-FC - Advanced Electrical Troubleshooting Kit

MPN: FLUKE-1587-FC SKU: 1130775
$2,254.00
Adding to cart… The item has been added

free shippingShipping Quote

(No reviews yet) Write a Review
Details

Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance. The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions.

Includes

  • Remote probe 
  • Test leads 
  • Alligator clips 
  • K-type thermocouple 
  • Soft case 
  • User documentation

Features

  • Fluke 1587 FC 2-in1 Insulation DMM
    • Pl/DAR measurements with TrendIt™ graphs 
    • Memory storage through Fluke Connect Measurements app 
    • Temperature Compensation through Fluke Connect Measurements app 
    • VFD low-pass filter for accurate motor drive measurements 
    • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V 
    • Auto-discharge of capacitive voltage 
    • Insulation test smoothing reading 
    • Auto power off 
    • Three-year warranty 

Specifications

  • Maximum voltage applied to any terminal and common: 1000 V
  • Storage temperature: -40°C to 60°C (-40°F to 140°F) 
  • Operating temperature: -20°C to 55°C (-4°F to 131°F)   
  • Temperature coefficient: 0.05 × (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F) 
  • Relative humidity 
    • Noncondensing:
      • 0% to 95% @ 10°C to 30°C (50°F to 86°F) 
      • 0% to 75% @ 30°C to 40°C (86°F to 104°F) 
      • 0% to 40% @ 40°C to 55°C (104°F to 131°F) 
  • Vibration: Random, 2 g, 5–500 Hz per MIL-PRF-28800F, Class 2 instrument  
  • Radio frequency communication: 2.4 GHz ISM Band  
  • Radio frequency certification: FCC: T68-FBLE, IC: 6627A-FBLE 
  • Batteries: Four AA batteries (NEDA 15A or IEC LR6)   
  • Battery life 
    • Meter use: 1000 hours 
    • Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.  
  • Size (H × W × L): 5.0 × 10.0 × 20.3 cm (1.97 × 3.94 × 8.00 in)  
  • Weight: 550 g (1.2 lb)   
  • Altitude 
    • Operating: 2000 m 
    • Storage: 12,000 m 
  • Over-range capability: 110% of range except for capacitance which is 100% 
  • Frequency overload protection: < 10 V Hz 
  • Fuse protection from A input: 0.44 A, 1000 V, IR 10 kA 

Accuracy Specifications

  • AC voltage measurement 
    • Range: 600.0 mV 
      • Resolution: 0.1 mV 
      • Accuracy 50 Hz to 60 Hz: ±(1% + 3) 
      • Accuracy 60 Hz to 5000 Hz: ±(2% + 3)   
    • Range: 6.000 V 
      • Resolution: 0.001 V 
      • Accuracy 50 Hz to 60 Hz: ±(1% + 3) 
      • Accuracy 60 Hz to 5000 Hz: ±(2% + 3)   
    • Range: 60.00 V 
      • Resolution: 0.01 V 
      • Accuracy 50 Hz to 60 Hz: ±(1% + 3) 
      • Accuracy 60 Hz to 5000 Hz: ±(2% + 3)   
    • Range: 600.0 V 
      • Resolution: 0.1 V 
      • Accuracy 50 Hz to 60 Hz: ±(1% + 3) 
      • Accuracy 60 Hz to 5000 Hz: ±(2% + 3)   
    • Range: 1000 V 
      • Resolution: 1 V 
      • Accuracy 50 Hz to 60 Hz: ±(2% + 3) 
      • Accuracy 60 Hz to 5000 Hz: ±(2% + 3) 
  • Low-Pass Filter Voltage 
    • Range: 600.0 mV 
      • Resolution: 0.1 mV 
      • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) 
      • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): ±(2% + 3), −(6% − 3)   
    • Range: 6.000 V 
      • Resolution: 0.001 V 
      • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) 
      • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): ±(2% + 3), −(6% − 3)   
    • Range: 60.00 V 
      • Resolution: 0.01 V 
      • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) 
      • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): ±(2% + 3), −(6% − 3)   
    • Range: 600.0 V 
      • Resolution: 0.1 V 
      • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) 
      • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): ±(2% + 3), −(6% − 3)   
    • Range: 1000 V 
      • Resolution: 1 V 
      • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3) 
      • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): ±(2% + 3), −(6% − 3)
  • DC Voltage Measurement 
    • Range/Resolution/Accuracy: 
      • 6.000 Vdc / 0.001 V / ±(0.09% + 2) 
      • 60.00 Vdc / 0.01 V / ±(0.09% + 2) 
      • 600.0 Vdc / 0.1 V / ±(0.09% + 2) 
      • 1000 Vdc / 1 V / ±(0.09% + 2) 
    • Input impedance: 10 MΩ (nominal), <100 pF 
    • Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz 
    • Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) 
    • Accuracies apply to 100% of range 
  • DC Millivolts Measurement 
    • Range/Resolution/Accuracy: 600.0 mVdc / 0.1 mV / ±(0.1% + 1)
  • DC and AC Current Measurement 
    • AC 45 Hz to 1000 Hz 
    • Range: 400 mA 
    • Resolution: 0.1 mA 
    • Accuracy: ±(1.5% + 2) 
    • Burden voltage (typical): 2 mV/mA 
    • Range: 60 mA 
    • Resolution: 0.01 mA 
    • Accuracy: ±(1.5% + 2) 
    • Burden voltage (typical): 2 mV/mA 
  • DC 
    • Range: 400 mA 
    • Resolution: 0.1 mA 
    • Accuracy: ±(0.2% + 2) 
    • Burden voltage (typical): 2 mV/mA 
    • Range: 60 mA 
    • Resolution: 0.01 mA 
    • Accuracy: ±(0.2% + 2) 
    • Burden voltage (typical): 2 mV/mA 
    • Overload: 600 mA for 2 minutes maximum 
    • Fuse protection for mA input: 0.44 A, 1000 V, IR 10 kA 
    • AC conversion: Inputs are AC-coupled and calibrated to the rms value of sine wave input 
  • Ohms Measurement 
    • Range/Resolution/Accuracy: 
      • 600.0 Ω / 0.1 Ω / ±(0.9% + 2) 
      • 6.000 kΩ / 0.001 kΩ / ±(0.9% + 2) 
      • 60.00 kΩ / 0.01 kΩ / ±(0.9% + 2) 
      • 600.0 kΩ / 0.1 kΩ / ±(0.9% + 2) 
      • 6.000 MΩ / 0.001 MΩ / ±(0.9% + 2) 
      • 50.0 MΩ / 0.01 MΩ / ±(1.5% + 3) 
    • Overload protection: 1000 V rms or dc 
    • Open circuit test voltage: < 8.0 V dc 
    • Short circuit current: < 1.1 mA 
  • Diode Test 
    • Diode test indication: Display voltage drop 0.6 V at 1.0 mA nominal test current 
    • Accuracy: ±(2% + 3)
  • Continuity Test 
    • Continuity indication: Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum reading: 1000 Ω 
    • Open circuit voltage: <8.0 V 
    • Short circuit current: 1.0 mA typical 
    • Overload protection: 1000 V rms 
    • Response time: >1 msec 
  • Frequency Measurement 
    • Range: 99.99 Hz 
    • Resolution: 0.01 Hz 
    • Accuracy: ±(0.1% + 1) 
    • Range: 999.9 Hz 
    • Resolution: 0.1 Hz 
    • Accuracy: ±(0.1% + 1) 
    • Range: 9.999 kHz 
    • Resolution: 0.001 kHz 
    • Accuracy: ±(0.1% + 1) 
    • Range: 99.99 kHz 
    • Resolution: 0.01 kHz 
    • Accuracy: ±(0.1% + 1) 
  • Frequency Counter Sensitivity 
    • 600.0 mV ac 
      • Vac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 100.0 mV 
      • Vac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: 150.0 mV 
      • DC Trigger Levels¹ to 20 kHz: NA 
    • 6.0 V 
      • Vac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 1.0 V 
      • Vac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: 1.5 V 
      • DC Trigger Levels¹ to 20 kHz: –400.0 mV and 2.5 V 
    • 60.0 V 
      • Vac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 10.0 V 
      • Vac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: 36.0 V 
      • DC Trigger Levels¹ to 20 kHz: 1.2 V and 4.0 V 
    • 600.0 V 
      • Vac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 100.0 V 
      • Vac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: – 
      • DC Trigger Levels¹ to 20 kHz: 12.0 V and 40.0 V 
    • 1000.0 V 
      • Vac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 300.0 V 
      • Vac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: – 
      • DC Trigger Levels¹ to 20 kHz: 12.0 V and 40.0 V 
  • Capacitance 
    • Range: 1000 nF 
    • Resolution: 1 nF 
    • Accuracy: ±(1.2% + 2) 
    • Range: 100.0 μF 
    • Resolution: 0.01 μF 
    • Accuracy: ±(1.2% + 2) 
    • Range: 1000 μF 
    • Resolution: 0.1 μF 
    • Accuracy: ±(1.2% + 90 counts) 
    • Range: 9999 μF 
    • Resolution: 1 μF 
    • Accuracy: ±(1.2% + 90 counts) 
  • Temperature Measurement 
    • Range: -40 °C to 537 °C 
    • Resolution: 0.1 °C 
    • Accuracy: ±(1% + 10 counts) 
    • Range: -40 °F to 998 °F 
    • Resolution: 0.1 °F 
    • Accuracy: ±(1% + 18 counts) 
  • Insulation Specifications 
    • Measurement range: 0.01 MΩ to 2 GΩ 
    • Test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V 
    • Test voltage accuracy: +20%, -0% 
    • Short-circuit test current: 1 mA nominal 
    • Auto discharge: Discharge time <0.5 second for C = 1 μF or less 
    • Live circuit detection: Inhibit test if terminal voltage >30 V prior to initialization of test 
    • Maximum capacitive load: Operable with up to 1 μF load 
  • Output Voltage 
    • 50 V (0% to +20%) 
      • Display range: 0.01 to 6.00 MΩ 
      • Resolution: 0.01 MΩ 
      • Test current: 1 mA @ 50 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(3% + 5 counts) 
      • Display range: 6.0 to 50.0 MΩ 
      • Resolution: 0.1 MΩ 
      • Test current: 1 mA @ 50 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(3% + 5 counts)   
    • 100 V (0% to +20%) 
      • Display range: 0.01 to 6.00 MΩ 
      • Resolution: 0.01 MΩ 
      • Test current: 1 mA @ 100 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(3% + 5 counts) 
      • Display range: 6.0 to 60.0 MΩ 
      • Resolution: 0.1 MΩ 
      • Test current: 1 mA @ 100 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(3% + 5 counts) 
      • Display range: 60 to 100 MΩ 
      • Resolution: 1 MΩ 
      • Test current: 1 mA @ 100 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(3% + 5 counts)   
    • 250 V (0% to +20%) 
      • Display range: 0.1 to 60.0 MΩ 
      • Resolution: 0.1 MΩ 
      • Test current: 1 mA @ 250 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(1.5% + 5 counts) 
      • Display range: 60 to 250 MΩ 
      • Resolution: 1 MΩ 
      • Test current: 1 mA @ 250 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(1.5% + 5 counts)   
    • 500 V (0% to +20%) 
      • Display range: 0.1 to 60.0 MΩ 
      • Resolution: 0.1 MΩ 
      • Test current: 1 mA @ 500 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(1.5% + 5 counts) 
      • Display range: 60 to 500 MΩ 
      • Resolution: 1 MΩ 
      • Test current: 1 mA @ 500 kΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(1.5% + 5 counts)   
    • 1000 V (0% to +20%) 
      • Display range: 0.1 to 60.0 MΩ 
      • Resolution: 0.1 MΩ 
      • Test current: 1 mA @ 1 MΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(1.5% + 5 counts) 
      • Display range: 60 to 600 MΩ 
      • Resolution: 1 MΩ 
      • Test current: 1 mA @ 1 MΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(1.5% + 5 counts) 
      • Display range: 0.6 to 2.0 GΩ 
      • Resolution: 100 MΩ 
      • Test current: 1 mA @ 1 MΩ 
      • Resistance accuracy (% of Rdg + Counts): ±(10% + 3 counts) 
  • Safety 
    • IEC 61010-1 
    • Pollution Degree 2 
    • IEC 61010-033 
    • CAT IV 600 V / CAT III 1000 V 
Categories
Shipping Info

Shipping Estimate

Please enter your postcode

Store Pickup
  • Free pickup is available at any of our WA stores.  Click here to find your closest store
Free Shipping
  • All items marked with "Free Shipping" will be shipped to any location in mainland Australia or Tasmania free of charge.
Australia Post [Satchel]
  • Items will be sent in an Australia Post Express Post satchel.
  • Delivery time is between 2-5 business days from despatch date.
Perth Metro Express
  • The Perth metro region includes all those within the postcode range 6000-6214 & 6800-6999
  • Orders are typically sent with Australia Post.
  • Delivery time is typically 1 business day from despatch date.
Fixed Rate [Parcel]
  • Orders will typically be sent by road transport with Australia Post or one of our Couriers.
  • Delivery time is between 2-10 business days from despatch date.
Courier Service
  • Heavy and/or bulky items will be shipped by road transport with one of our couriers.
  • Orders shipped with a courier can only be delivered to a fixed address (PO Boxes not accepted)
  • Courier deliveries to residential addresses (ie. someone lives there) will incur additional freight charges. The appropriate shipping option should be selected on checkout.
  • If the non-residential option is selected in error at checkout we'll contact you after your order is placed to request additional payment or to arrange delivery to an alternative non-residential address. We could, for example, ship your order to a friend or family members place of business.
  • If you can't use a non-residential shipping address you can choose to have your order delivered to your local freight depot. Simply select the "Non-Residential" shipping option and enter your shipping street address as "C/O Freight Depot" at checkout. The courier company will contact you directly and provide further instructions when your order is ready for pickup.
  • Delivery time is between 2-10 business days from despatch date.
  • Courier deliveries to remote Australian islands may incur additional freight charges.

Delivery Times

Delivery times will vary depending on your location but will generally take between 1-10 business days. Currently stocked items will be despatched same day or next day. Unfortunately it is not possible for us to carry all stock items 100% of the time. If an item is out of stock we will order from our supplier immediately and mark your order as priority.

Warranty & Returns

Warranty

Tools covered by manufacturers warranty can be returned to us or your nearest authorised warranty agent for repair or replacement.  Find out More.

Returns

If you are not satisfied with a purchased item it may be returned to us within 30 days and we'll give you a refund (excluding delivery costs). All merchandise must be returned in original packing, unused and include a copy of your invoice. Please contact us prior to returning an order so we can assure quick processing of the cancellation.