Details

Connect the v3000 FC Wireless AC Voltage and v3001 FC Wireless DC Voltage Modules to your test points, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter. You'll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect® modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless Voltage Modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm's way.

Includes

  • TL175 Test Leads
  • TL224 Test Leads
  • TL222 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • AC220 Alligator Clips
  • Magnetic hanging straps

Features

Fluke 3000 FC Series Wireless Multimeter

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

Fluke v3000 FC Wireless AC Voltage Module

  • Measure up to 1000 V True-RMS AC
  • Use as a standalone meter or as part of the system
  • Use the logging function for recording and saving up to 65,000 readings

Fluke v3001 FC Wireless DC Voltage Module

  • Measure up to 1000 V DC
  • Use as a standalone meter or as part of the system
  • Use the logging function for recording and saving up to 65,000 readings

Specifications

Fluke 3000 FC Wireless Digital Multimeter

  • Maximum voltage between any terminal and earth ground: 1000 VDC or AC rms
  • Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
  • Display (LCD)
    • Update rate: 4/sec
    • Volts, amps, ohms: 6000 counts
    • Frequency: 10,000 counts
    • Capacitance: 1,000 counts
  • Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6
  • Battery life: 250 hours minimum
  • RF communications
    • Band: 2.4 GHZ ISM Band
    • Open air, unobstructed: Up to 20 m
    • Obstructed, sheetrock wall: Up to 6.5 m
    • Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m
  • Temperature
    • Operating: -10°C to 50°C
    • Storage: -40°C to 60°C
    • Temperature coefficient: 0.1 x (specified accuracy) / °C (<18°C or >28°C)
  • Relative humidity
    • 0% to 90% (0°C to 35°C)
    • 0% to 75% (35°C to 40°C)
    • 0% to 45% (40°C to 50°C)
  • Altitude
    • Operating: 2,000 m
    • Storage: 12,000 m
  • Electromagnetic compatibility
    • EMI, RFI, EMC, RF: EN 61326-1:2006, EN 61326-2-2:2006
    • ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008
    • FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    • FCCID: FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
  • Safety compliance
    • ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    • CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    • UL 61010-1: 3rd edition
    • IEC/EN 61010-1: 2010
  • Certifications: CSA, FCC, CE
  • Ingress Protection (IP) rating: IP54
  • Pollution degree: 2
  • Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
  • Weight: 340 g (12 oz)
  • Warranty: Three years

Fluke v3000 FC Wireless AC Voltage Module

  • LCD w/ backlight: 3½ digits, 6000 counts, updates 4/sec
  • Battery type: 2 AA, NEDA 15 A, IEC LR6
  • Battery life: 400 Hours
  • Memory: Record up to 65000 readings
  • RF communications: 2.4 GHZ ISM Band
  • RF communication range
    • Open air, unobstructed: Up to 20 m
    • Obstructed, sheetrock wall: Up to 6.5 m
    • Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
  • Operating temperature: -10°C to +50°C
  • Storage temperature: -40°C to +60°C
  • Temperature coefficient: 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
  • Operating humidity: 90% at 35°C, 45% at 40°C, 45% at 50°C
  • Altitude
    • Operating: 2,000 m
    • Storage: 12,000 m
  • EMC: EN 61326-1:2006
  • Safety compliance
    • ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    • CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    • UL 61010-1: 3rd edition
    • IEC/EN 61010-1: 2010
  • Safety rating: CAT IV 600 V, CAT III 1000 V
  • Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
  • Ingress Protection (IP) rating: IP42
  • Pollution Degree: 2
  • Size (H x W x D): 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
  • Weight: .22 kg (8 oz)
  • Warranty: Three years
  • Range / Resolution
    • 6.000 V / 0.001 V
    • 60.00 V / 0.01 V
    • 600.0 V / 0.1 V
    • 1000 V / 1 V
  • Accuracy
    • 45 Hz to 500 Hz: 1.0% + 3
    • 500 Hz to 1 kHz: 2.0% + 3

Fluke v3001 FC Wireless DC Voltage Module

  • LCD w/ backlight: 3 ½ digits, 6000 counts, 4/sec update rate
  • Battery type: 2 AA Alkaline batteries, NEDA 15A, IEC LR6
  • Log rate/interval: Adjustable by PC from 1 sec to 1 hr, default 1 min
  • Battery life: 400 hours minimum
  • Memory: Record up to 65,000 readings
  • RF communications: 2.4 GHz ISM Band
  • RF communication range
    • Open air, unobstructed: Up to 20 m
    • Obstructed, sheetrock wall: Up to 6.5 m
    • Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
  • Operating temperature: -10°C to +50°C
  • Storage temperature: -40°C to +60°C
  • Temperature coefficient: 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
  • Relative humidity
    • 0% to 90% (0°C to 35°C)
    • 0% to 75% (35°C to 40°C)
    • 0% to 45% (40°C to 50°C)
  • EMC: IEC 61236-1, Portable
  • Safety compliance: IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2
  • Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
  • Ingress Protection (IP) rating: IP42
  • Size (H x W x D): 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
  • Weight: 0.255 kg (9 oz)
  • Warranty: Three years
  • Function
    • mVDC: Range 600.0 mV / Resolution 0.1 mV, Accuracy 0.09% + 3
    • VDC: Range 6.000 V / Resolution 0.001 V, Accuracy 0.09% + 3
    • VDC: Range 60.00 V / Resolution 0.01 V
    • VDC: Range 600.0 V / Resolution 0.1 V
    • VDC: Range 1000 V / Resolution 1 V, Accuracy 0.15% + 2

Accuracy Specifications

  • AC Voltage
    • 600.0 mV: Resolution 0.1 mV, Accuracy 1.0% + 3 (45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
    • 6.000 V: Resolution 0.001 V
    • 60.00 V: Resolution 0.01 V
    • 600.0 V: Resolution 0.1 V
    • 1000 V: Resolution 1 V
    • All AC voltage ranges specified from 1% of range to 100% of range
    • Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V
    • For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3
    • Do not exceed 107 V-Hz
  • DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    • mV: 600.0 mV, Resolution 0.1 mV, Accuracy 0.09% + 2
    • V: 6.000 V, Resolution 0.001 V, Accuracy 0.09% + 2
    • V: 60.00 V, Resolution 0.01 V
    • V: 600.0 V, Resolution 0.1 V
    • V: 1000 V, Resolution 1 V, Accuracy 0.15% + 2
    • Ω: 600 Ω, Resolution 1 Ω, Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer
    • Ω: 600.0 Ω, Resolution 0.1 Ω, Accuracy 0.5% + 2
    • Ω: 6.000 kΩ, Resolution 0.001 kΩ, Accuracy 0.5% + 1
    • Ω: 60.00 kΩ, Resolution 0.01 kΩ
    • Ω: 60.00 kΩ, Resolution 0.1 kΩ
    • Ω: 600.0 kΩ, Resolution 0.001 MΩ
    • Ω: 50.00 MΩ, Resolution 0.01 MΩ, Accuracy 1.5% + 3
    • Diode test: 2.000 V, Resolution 0.001 V, Accuracy 1% + 2
    • µF: 1000 nF, Resolution 1 nF, Accuracy 1.2% + 2
    • µF: 10.00 μF, Resolution 0.01 μF
    • µF: 100.0 μF, Resolution 0.1 μF
    • µF: 9999 μF, Resolution 1 μF, Accuracy 10% typical
    • In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2
  • AC and DC Current
    • mA AC (45 Hz to 1 kHz): 60.00 mA, Resolution 0.01 mA, Accuracy 1.5% + 3
    • mA AC: 400.0 mA, Resolution 0.1 mA
    • mA DC: 60.00 mA, Resolution 0.01 mA, Accuracy 0.5% + 3
    • mA DC: 400.0 mA, Resolution 0.1 mA
    • All AC current ranges specified from 5% of range to 100% of range
    • Input burden voltage (typical): 400 mA input 2 mV/mA
    • 400.0 mA accuracy specified up to 600 mA overload
  • Frequency
    • 99.99 Hz, Resolution 0.01 Hz, Accuracy 0.1% + 1
    • 999.9 Hz, Resolution 0.1 Hz
    • 9.999 kHz, Resolution 0.001 kHz
    • 99.99 kHz, Resolution 0.01 kHz
    • Frequency specified up to 99.99 kHz in volts and up to 10 kHz in amps
  • Input Characteristics
    • Overload protection: 1100 Vrms
    • Input impedance (nominal): > 10 MΩ < 100 pF
    • Common mode rejection ratio (1 kΩ unbalance): > 120 dB at DC, 50 Hz or 60 Hz
    • Normal mode rejection: > 60 dB at 50 Hz or 60 Hz
    • Common mode rejection ratio (1 kΩ unbalance): > 60 dB, DC to 60 Hz
  • Open circuit test voltage
    • To 6 MΩ: Full scale voltage < 2.7 VDC, Typical short circuit current < 350 mA
    • 50 MΩ: Full scale voltage 2.000 VDC, Typical short circuit current < 1.1 mA
  • mA Function
    • Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
    • Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
  • MIN/MAX Recording Accuracy
    • DC functions: ±12 counts for changes > 350 mS in duration
    • AC functions: ±40 counts for changes > 900 mS in duration
Categories
Shipping Info

Shipping Estimate

Please enter your postcode

Store Pickup
  • Free pickup is available at any of our WA stores.  Click here to find your closest store
Free Shipping
  • All items marked with "Free Shipping" will be shipped to any location in mainland Australia or Tasmania free of charge.
Australia Post [Satchel]
  • Items will be sent in an Australia Post Express Post satchel.
  • Delivery time is between 2-5 business days from despatch date.
Perth Metro Express
  • The Perth metro region includes all those within the postcode range 6000-6214 & 6800-6999
  • Orders are typically sent with Australia Post.
  • Delivery time is typically 1 business day from despatch date.
Fixed Rate [Parcel]
  • Orders will typically be sent by road transport with Australia Post or one of our Couriers.
  • Delivery time is between 2-10 business days from despatch date.
Courier Service
  • Heavy and/or bulky items will be shipped by road transport with one of our couriers.
  • Orders shipped with a courier can only be delivered to a fixed address (PO Boxes not accepted)
  • Courier deliveries to residential addresses (ie. someone lives there) will incur additional freight charges. The appropriate shipping option should be selected on checkout.
  • If the non-residential option is selected in error at checkout we'll contact you after your order is placed to request additional payment or to arrange delivery to an alternative non-residential address. We could, for example, ship your order to a friend or family members place of business.
  • If you can't use a non-residential shipping address you can choose to have your order delivered to your local freight depot. Simply select the "Non-Residential" shipping option and enter your shipping street address as "C/O Freight Depot" at checkout. The courier company will contact you directly and provide further instructions when your order is ready for pickup.
  • Delivery time is between 2-10 business days from despatch date.
  • Courier deliveries to remote Australian islands may incur additional freight charges.

Delivery Times

Delivery times will vary depending on your location but will generally take between 1-10 business days. Currently stocked items will be despatched same day or next day. Unfortunately it is not possible for us to carry all stock items 100% of the time. If an item is out of stock we will order from our supplier immediately and mark your order as priority.

Warranty & Returns

Warranty

Tools covered by manufacturers warranty can be returned to us or your nearest authorised warranty agent for repair or replacement.  Find out More.

Returns

If you are not satisfied with a purchased item it may be returned to us within 30 days and we'll give you a refund (excluding delivery costs). All merchandise must be returned in original packing, unused and include a copy of your invoice. Please contact us prior to returning an order so we can assure quick processing of the cancellation.