The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Features

  • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600 V safety rating

Specifications

  • Head circumference: 610 mm (24 in)
  • Head cable diameter: 14.3 mm (0.56 in)
  • Head bend radius: 38.1 mm (1.5 in)
  • Cable length (head to electronics): 2 m (6.56 ft)
  • Output connection: Molded 4 mm safety plugs (not integrated)
  • Temperature ranges
    • Operating temperature: 0°C to +70°C (32°F to 158°F) (head and electronics)
    • Storage temperature:
      • Head: -40°C to +105°C (-40°F to 221°F)
      • Electronics: -20°C to +85°C (-4°F to 185°F)
  • Operating humidity: 15% to 85% (non-condensing)
  • Weight
    • Head: 180 g (6.34 oz)
    • Electronics: 190 g (6.70 oz)
  • Safety standards
    • EN 61010-031: 2002
    • EN 61010-2-032: 2002
    • EN 61010-1: 2001
    • 600 Vrms, Category III, Pollution Degree 2
    • Use on uninsulated conductors limited to 600 V ac rms or dc and frequencies below 1 kHz
  • EMC standards
    • EN 61326: 1998 + A1, A2, and A3
  • Dimensions (H × W × D): 116 × 68.5 × 30 mm (4.56 × 2.69 × 1.18 in)

Accuracy Specifications

  • Current ranges
    • 20 A
    • 200 A
    • 2000 A
    • AC rms
  • Output sensitivity (AC-coupled)
    • 1 mV
    • 10 mV
    • 100 mV
    • 1 mV per A
  • Load impedance: 100 kΩ minimum
  • Accuracy (at +25°C)
    • ±1% of range (45 Hz to 65 Hz)
  • Linearity
    • Range: 10% to 100% of range
    • Accuracy: ±0.2% of reading
  • Noise
    • 8 mV AC rms (30 A)
    • 2 mV AC rms (300 A, 3000 A)
  • Frequency range: 10 Hz to 20 kHz (-3 dB)
  • Phase error
    • < ±1° (45 Hz to 65 Hz)
    • ±10° (at 20 kHz)
  • Position sensitivity (with cable > 25 mm from the coupling)
    • From 1% up to 3% of range with cable, depending on distance from center
    • Measurements closer than 25 mm from the coupling are typically > 3% of range
  • External wire influence
    • 1% (-40 dB) of external current > 200 mm from head
  • External field (with cable > 200 mm from the head)
    • ±1% of range
  • Power supply
    • 2 × AA / MN1500 / LR6 alkaline batteries
    • Battery life: approx. 200 hours
    • Low battery indicator
  • Temperature coefficient: ±0.08% of reading per °C
  • Working voltage
    • See Safety standards section
    • 600 V AC rms or DC
Categories
Shipping Info

Shipping Estimate

Please enter your postcode

Store Pickup
  • Free pickup is available at any of our WA stores.  Click here to find your closest store
Free Shipping
  • All items marked with "Free Shipping" will be shipped to any location in mainland Australia or Tasmania free of charge.
Australia Post [Satchel]
  • Items will be sent in an Australia Post Express Post satchel.
  • Delivery time is between 2-5 business days from despatch date.
Perth Metro Express
  • The Perth metro region includes all those within the postcode range 6000-6214 & 6800-6999
  • Orders are typically sent with Australia Post.
  • Delivery time is typically 1 business day from despatch date.
Fixed Rate [Parcel]
  • Orders will typically be sent by road transport with Australia Post or one of our Couriers.
  • Delivery time is between 2-10 business days from despatch date.
Courier Service
  • Heavy and/or bulky items will be shipped by road transport with one of our couriers.
  • Orders shipped with a courier can only be delivered to a fixed address (PO Boxes not accepted)
  • Courier deliveries to residential addresses (ie. someone lives there) will incur additional freight charges. The appropriate shipping option should be selected on checkout.
  • If the non-residential option is selected in error at checkout we'll contact you after your order is placed to request additional payment or to arrange delivery to an alternative non-residential address. We could, for example, ship your order to a friend or family members place of business.
  • If you can't use a non-residential shipping address you can choose to have your order delivered to your local freight depot. Simply select the "Non-Residential" shipping option and enter your shipping street address as "C/O Freight Depot" at checkout. The courier company will contact you directly and provide further instructions when your order is ready for pickup.
  • Delivery time is between 2-10 business days from despatch date.
  • Courier deliveries to remote Australian islands may incur additional freight charges.

Delivery Times

Delivery times will vary depending on your location but will generally take between 1-10 business days. Currently stocked items will be despatched same day or next day. Unfortunately it is not possible for us to carry all stock items 100% of the time. If an item is out of stock we will order from our supplier immediately and mark your order as priority.

Warranty & Returns

Warranty

Tools covered by manufacturers warranty can be returned to us or your nearest authorised warranty agent for repair or replacement.  Find out More.

Returns

If you are not satisfied with a purchased item it may be returned to us within 30 days and we'll give you a refund (excluding delivery costs). All merchandise must be returned in original packing, unused and include a copy of your invoice. Please contact us prior to returning an order so we can assure quick processing of the cancellation.