The Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.
The 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations.
Includes
- Holster
- Installed 9V battery
- TL75 test lead set
- Quick Reference Guide
Features
- Compact True-rms digital multimeter for field service
- Includes: meter, holster, TL75 test lead set
- Easy one-handed operation of the meter
- Min/Max/Average to record signal fluctuations
Specifications
- Maximum voltage between any terminal and earth ground: 600 V
- Safety IEC 61010-1: Pollution Degree 2
- IEC 61010-2-033: CAT III 600V
- Display: Digital - 6,000 counts, updates 4 per second
- Bar graph: 33 segments, updates 32 per second
- Operating temperature: -10℃ to + 50℃
- Storage temperature: -40℃ to + 60℃
- Battery type: 9 volt Alkaline, IEC 6LR61
- Battery life: 400 hours typical, without backlight
- Size: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
- Weight: 550 g
- Warranty: 3 years
Accuracy Specifications
- DC Millivolts
- Range / Resolution: 600.0 mV / 0.1 mV
- Accuracy: ±[(% of reading) + (counts)]: 0.5% + 2
- DC Volts
- Range / Resolution:
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- Accuracy: ±[(% of reading) + (counts)]: 0.5% + 2
- Range / Resolution:
- AC Millivolts (True RMS)
- Range / Resolution: 600.0 mV / 0.1 mV
- Accuracy:
- 1.0% + 3 (DC, 45 Hz to 500 Hz)
- 2.0% + 3 (500 Hz to 1 kHz)
- AC Volts (True RMS)
- Range / Resolution:
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- Accuracy:
- 1.0% + 3 (DC, 45 Hz to 500 Hz)
- 2.0% + 3 (500 Hz to 1 kHz)
- Range / Resolution:
- Continuity
- Range / Resolution: 600 Ω / 1 Ω
- Accuracy:
- Beeper ON: < 20 Ω
- Beeper OFF: > 250 Ω
- Detects opens or shorts ≥ 500 µs
- Ohms
- Range / Resolution:
- 600.0 Ω / 0.1 Ω
- 6.000 kΩ / 0.001 kΩ
- 60.00 kΩ / 0.01 kΩ
- 600.0 kΩ / 0.1 kΩ
- 6.000 MΩ / 0.001 MΩ
- Accuracy: 0.9% + 1
- Range / Resolution: 40.00 MΩ / 0.01 MΩ
- Accuracy: 5% + 2
- Range / Resolution:
- Diode Test
- Range / Resolution: 2.00 V / 0.001 V
- Accuracy: 0.9% + 2
- Capacitance
- Range / Resolution:
- 1000 nF / 1 nF
- 10.00 µF / 0.01 µF
- 100.0 µF / 0.1 µF
- 999.9 µF / 1 µF
- 100 µF to 1000 µF
- Accuracy: 1.9% + 2
- Range / Resolution: > 1000 µF
- Accuracy: 5% + 20%
- Range / Resolution:
- Lo-Z Capacitance
- Range: 1 nF to 500 µF
- Accuracy: 10% + 2 typical
- AC Amps (True RMS, 45 Hz to 500 Hz)
- Range / Resolution:
- 6.000 A / 0.001 A
- 10.00 A / 0.01 A
- Accuracy:
- 1.5% + 3
- 20 A overload for 30 seconds max
- Range / Resolution:
- DC Amps
- Range / Resolution:
- 6.000 A / 0.001 A
- 10.00 A / 0.01 A
- Accuracy:
- 1.0% + 3
- 20 A overload for 30 seconds max
- Range / Resolution:
- Hz (V or A input)
- Range / Resolution:
- 99.99 Hz / 0.01 Hz
- 999.9 Hz / 0.01 Hz
- 9.999 kHz / 0.001 kHz
- 50.00 kHz / 0.01 kHz
- Accuracy: 0.1%
- Range / Resolution:
Categories
Fluke » Precision Measuring » Precision Measuring & Testing » Measure & Test » All Tools
Brand
Shipping Estimate
Please enter your postcode
- Free pickup is available at any of our WA stores. Click here to find your closest store
- All items marked with "Free Shipping" will be shipped to any location in mainland Australia or Tasmania free of charge.
- Items will be sent in an Australia Post Express Post satchel.
- Delivery time is between 2-5 business days from despatch date.
- The Perth metro region includes all those within the postcode range 6000-6214 & 6800-6999
- Orders are typically sent with Australia Post.
- Delivery time is typically 1 business day from despatch date.
- Orders will typically be sent by road transport with Australia Post or one of our Couriers.
- Delivery time is between 2-10 business days from despatch date.
- Heavy and/or bulky items will be shipped by road transport with one of our couriers.
- Orders shipped with a courier can only be delivered to a fixed address (PO Boxes not accepted)
- Courier deliveries to residential addresses (ie. someone lives there) will incur additional freight charges. The appropriate shipping option should be selected on checkout.
- If the non-residential option is selected in error at checkout we'll contact you after your order is placed to request additional payment or to arrange delivery to an alternative non-residential address. We could, for example, ship your order to a friend or family members place of business.
- If you can't use a non-residential shipping address you can choose to have your order delivered to your local freight depot. Simply select the "Non-Residential" shipping option and enter your shipping street address as "C/O Freight Depot" at checkout. The courier company will contact you directly and provide further instructions when your order is ready for pickup.
- Delivery time is between 2-10 business days from despatch date.
- Courier deliveries to remote Australian islands may incur additional freight charges.
Delivery Times
Delivery times will vary depending on your location but will generally take between 1-10 business days. Currently stocked items will be despatched same day or next day. Unfortunately it is not possible for us to carry all stock items 100% of the time. If an item is out of stock we will order from our supplier immediately and mark your order as priority.
Warranty
Tools covered by manufacturers warranty can be returned to us or your nearest authorised warranty agent for repair or replacement. Find out More.
Returns
If you are not satisfied with a purchased item it may be returned to us within 30 days and we'll give you a refund (excluding delivery costs). All merchandise must be returned in original packing, unused and include a copy of your invoice. Please contact us prior to returning an order so we can assure quick processing of the cancellation.